BZRNF - GLASS CLEANER 125
- MSDS: BZRNF
- Manufacturer: PRECISION SUPPLY
- Product Name: GLASS CLEANER 125
- National Stock Number: 7930-00N065695
Product Identification
Product ID:GLASS CLEANER 125
MSDS Date:11/14/1988
FSC:7930
NIIN:00N065695
MSDS Number: BZRNF
Responsible Party
BAKERSFIELD, CA 93309
US
Emergency Phone: 305-974-5440
Info Phone: 209-732-9343
Cage: JO046
Contractor
Telephone: 305-974-5440
Cage: JO046
Ingredients
ISOPROPYL ALCOHOL (SARA 313)
CAS: 67-63-0
RTECS: NT8050000
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM/500STEL
OP-7; (NON-IONIC SURFACTANTS)
CAS: 9004-87-9
RTECS: RL1070000
OSHA PEL N/K
ACGIH TLV: N/K
PROPANE (PROPELLANT)
CAS: 74-98-6
RTECS: TX2275000
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
BUTANE (PROPELLANT)
CAS: 106-97-8
RTECS: EJ4200000
OSHA PEL 800 PPM
ACGIH TLV: 800 PPM
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION:PRODUCTS EXISTS AS A FOAM.
INHALATION OF VAPORS ARE AN UNLIKELY ROUTE OF EXPOSURE. NO HARMFUL
EFFECTS KNOWN FROM AVAILABLE INFORMATION. SKIN CONT/ABSORP:NO
EVIDENCE OF ADVERSE EFTS FROM AVA IL INFO. PRLNGD/RPTD CONT MAY
CAUSE IRRIT. INGEST:CAN CAUSE GI IRRIT, NAUS, VOMIT & DIARR. ASPIR
OF (EFTS OF OVEREXP)NO
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:MATERIAL INTO LUNGS CAN CAUSE
CHEMICAL PNEUMONITIS. EYES:CAN CAUSE SEVERE IRRITATION, REDNESS,
TEARING AND BLURRED VISION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . TREAT FOR STRANGULATION. EYES:FLUSH WITH WATER FOR AT LEAST
15 MINUTES, LIFTING UPPER AND LOWER LIDS. GET MEDICAL ATTENTION. S
KIN:WASH EXPOSED AREAS WITH SOAP AND WATER. INGESTION:DILUTE WITH
WATER, DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT TO PROTECT PERSONNEL AGAINST BURSTING,
RUPTURING OR VENTING CONTAINERS.
Unusual Fire/Explosion Hazard:AT ELEVATED TEMPERATURES (ABOVE 120F)
CONTAINERS MAY VENT, RUPTURE OR BURST.
Accidental Release
Spill Release Procedures:CLEAN UP AREA BY MOPPING OR WITH ABSORBENT
MATERIALS AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL. CONTACT
FEDERAL, STATE OR LOCAL AUTHORITIES FOR APPROVED DISPOSAL
PROCEDURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE
120F.
Other Precautions:PLEASE READ & FOLLOW THE DIRECTIONS ON THE PRODUCT
LABEL. THEY ARE YOUR BEST GUIDE TO USING THIS PRODUCT IN THE MOST
EFFECTIVE WAY, AND THEY ALSO GIVE THE NECESSARY SAFETY PRECAUTIONS
TO PROTECT YOUR HEALTH.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . UNDER NORMAL CONDITIONS, NO RESPIRATORY
PROTECTION IS REQUIRED.
Ventilation:NORMAL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER .
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREA. WASH
HANDS BEFORE EATING.
Supplemental Safety and Health
SPEC GRAV:0.978 @ 75F (H*2O=1). VP:55 (PSIG) IN CAN @ 75F. EYE PROT:AND
FULL LENGTH FACE SHIELD .
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SUPP DATA
Spec Gravity:SUPP DATA
Solubility in Water:COMPLETE
Appearance and Odor:WHITE FOAM WITH A SLIGHT AMMONIA ODOR.
Percent Volatiles by Volume:96
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES, SELECTED AMINES.
Stability Condition to Avoid:DO NOT EXPOSE TO TEMPERATURES ABOVE 120F.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN THE PRESENCE
OF AIR MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:WHEN USED PROPERLY, AEROSOL PRODS DO NOT
GENERATE HAZ WASTE. EMPTY DE-PRESSURIZED CONTAINERS CAN NOT BE
REUSED AND SHOULD BE WRAPPED AND PUT IN A PERMITTED WASTE
MANAGEMENT FACILITY. CONSULT FEDERAL, STATE AND LOCAL AUTHS FOR
APPRVD PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.